FlowGearSourceIndustrial pumps, valves, fittings, and process equipment for global buyers and RFQ-led sourcing.
Automatic Industrial Ton Oil Gas Liquefied Natural-Gas Heavy-Oil Steam Boi
Industrial Pumps

Automatic Industrial Ton Oil Gas Liquefied Natura | RFQ Sourcing Details

Industrial Pumps · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryHeat Exchanger Skids
Unitset
FuelOil or Gas or Oil and Gas
MediaSteam
UsageIndustrial, Home, Vehicle, Power Station
OriginChina
Diameter(mm) Condenser Inlet
CategoryIndustrial Pumps
CategoryIndustrial Pumps
AvailabilityInquiry required
Updated2026-05-27

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Industrial Pumps. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Model No.

YQLW - 50 - V YQLW - 100 - V YQLW - 150 - V YQLW - 200 - V YQLW - 300 - V YQLW - 400 - V YQLW - 500 - V YQLW - 600 - V YQLW - 800 - V YQLW - 1000 - V YQLW - 1200 - V YQLW - 1500 - V YQLW - 2000 - V YQLW - 2500 - V YQLW - 3000 - V YQLW - 3500 - V YQLW - 4000 - V YQLW - 5000 - V YQLW - 6000 - V Cooling Capacity (10^4 k.

Cal/h) Heating Capacity (kW) Rated Power (kW) Heating Efficiency (%) ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 ≥90 Noise (dB(A)) ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 ≤92 Design Working Pressure (MPa) Evaporator Inlet Diameter (mm) Condenser Inlet Diameter (mm) Medium Working Temperature (°C) Cooling Water Temperature (°C) Air Content in Furnace (m³/h) Main Air Inlet (mm) Main Air Outlet (mm) Fuel Gas Pressure (k.

Pa) Fuel Gas Consumption (m³/h) 29.625/ Boiler Weight (kg) Boiler Dimensions (mm) Φ325×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Φ406×6.5 Length × Width × Height (mm) 1500×1000× ×1000× ×1000× ×1000× ×1000× ×1000× ×1000× ×1000× ×1000× ×1000× ×1000× ×1000× ×1000×2500 Circulating Water Volume (m³/h) Cooling Water Pressure (k.

Pa) Product application

Automatic | Applications and Buyer Notes

Automatic is organized as a sourcing-ready Industrial Pumps reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questi

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

1
Unit, setBased on visible page data; confirm exact value in the RFQ.
2
Fuel, Oil or Gas or Oil and GasBased on visible page data; confirm exact value in the RFQ.
3
Media, SteamBased on visible page data; confirm exact value in the RFQ.
4
Usage, Industrial, Home, Vehicle, Power StationBased on visible page data; confirm exact value in the RFQ.
5
Origin, ChinaBased on visible page data; confirm exact value in the RFQ.
6
Diameter, (mm) Condenser InletBased on visible page data; confirm exact value in the RFQ.
7
Category, Industrial PumpsBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryHeat Exchanger Skids
Brand
Unitset
FuelOil or Gas or Oil and Gas
MediaSteam
UsageIndustrial, Home, Vehicle, Power Station
OriginChina
Diameter(mm) Condenser Inlet
FunctionSteam Boilers, Hot Water Boiler, Packaged Boiler
PressureLow Pressure
Model NO.Customizable
StructureFire Tube
TrademarkHD
InstallationPackaged Boiler
Work PressureCan Be Designed According to Customer Needs
Drum PlacementHorizontal Boiler
Design Pressure0.8-1.1MPa
Boiler ParametersCan Be Designed
Water CirculationForced Circulation
Manufacturing LevelA
Rated Thermal Power30-36 Million Kcal/H-42MW

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

FlowGearSource related sourcing paths

Related categories FlowGearSource related paths

Industrial Pumps

Industrial Valves

Centrifugal Pumps

Related applications FlowGearSource related paths

Oil and Gas Transfer

Water Treatment

Related solutions FlowGearSource related paths

High Pressure Process Lines

Low Maintenance Pump Sourcing

FlowGearSource procurement phrases

FlowGearSource related product samples

Supplier profile

Jiangsu Hai De Li Thermal Energy Equipment Manufacturing Co., Ltd.
主营:Heat Exchanger Skids

Jiangsu Hai De Li Thermal Energy Equipment Manufacturing Co., Ltd. focuses on heat exchanger skids for flow control equipment sourcing, industrial pump and valve discovery, and rfq-ready process supply platform

View full profile >